Connect Tech FreeForm/PCI-104 User Manual
Revision 0.07 24
11) Right click on the second device in the JTAG chain and click Assign New Configuration File
12) Browse to the bsdl folder and select PCI9056BA.bsd
Example: {REFDIR}\fpga\bsdl\PCI9056BA.bsd
13) Right click on the second device in the JTAG chain and click Assign New Configuration File
14) Browse to the bsdl folder and select DP83849IVS.bsd.
Example: {REFDIR}\fpga\bsdl\ DP83849IVS.bsd
15) To test stream integrity, right click on the FPGA and select Get Device ID. The console will
report Manufacturer's ID = Xilinx xc5vlx30t
INFO:iMPACT - Current time: 2013-03-25 3:01:12 PM
// *** BATCH CMD : ReadIdcode -p 1
Maximum TCK operating frequency for this device chain: 10000000.
Validating chain...
Boundary-scan chain validated successfully.
1: Device Temperature: Current Reading: -273.00 C
1: VCCINT Supply: Current Reading: 0.000 V
1: VCCAUX Supply: Current Reading: 0.000 V
'1': IDCODE is '11000010101001101110000010010011'
'1': IDCODE is 'c2a6e093' (in hex).
'1': : Manufacturer's ID = Xilinx xc5vlx30t, Version : 12
16) Save the iMPACT project (File -> Save Project As)
Example: {REFDIR}\fpga\\ise_projects\ref_design_fcg001rd\ ref_design_fcg001rd.ipf