Pagina 1 - Connect Tech Inc

Connect Tech Inc. “Industrial Strength Communications” Echo/ISA Multi-port Serial Communications Adapters User Manual Connect Tech Inc 42 Arrow Road…

Pagina 3 - Limited Lifetime Warranty

Warranty i Echo User's Manual, ver. 0.00 Limited Lifetime Warranty Connect Tech Inc. provides a Lifetime Warranty for all Connect Tech Inc. products.…

Pagina 4 - Trademark Acknowledgment

ii Copyright/Trademarks Echo User's Manual, ver. 0.00 Copyright Notice The information contained in this document is subject to change without notice.…

Pagina 5

iii Echo User's Manual, ver. 0.00 Table of Contents Chapter 1: Introduction Conventions & Symbols 1-1 Product Overview 1-2 Echo Adapter 1-2 Echo…

Pagina 6

iv Contents Echo User's Manual, ver. 0.00 Windows 95 3-29 Echo Enhanced Driver 3-30 Installation 3-31 UART/FIFO Configuration 3-32 Configuration 3-33…

Pagina 7

Contents v Echo User's Manual, ver. 0.00 List of Tables Table 1: Typical port address usage 2-2 Table 2: Switch settings(Echo) 2-1 Table 3: Typical…

Pagina 8

Conventions & Symbols 1-1 Product Overview 1-2 Echo Adapter 1-2 Echo Software 1-3 Customer Service Overview 1-3 RMA Overview 1-6

Pagina 9

Conventions & Symbols This manual uses the following conventions: In most cases the font for file names and command statements is Arial Narrow Bold…

Pagina 10

Product Overview The Echo adapters are high performance multi-port serial adapters that allow you to connect up to 8 serial devices through one…

Pagina 11

The Echo adapters can accommodate both small and large multi- channel applications. You can combine different Echo adapters in a single computer, up…

Pagina 12

Figure 1: Problem summary sheet Problem Description Connect Tech Product Description Product: Revision no.: Product serial no.: No. of serial ports…

Pagina 13

We offer three ways for you to contact us: Mail/Courier You may contact us by letter and our mailing address for correspondence is: Connect Tech Inc.…

Pagina 14

RMA Overview Connect Tech products requiring warranty or non warranty repairs need an RMA number. To obtain a Return Merchandise Authorization (RMA)…

Pagina 15

Include with the product, proof of purchase (including date of purchase), a description of the problem and the RMA number. Clearly display the RMA…

Pagina 16

Introduction 2-1 Configuration 2-1 Port Addresses 2-2 Custom Port Addresses 2-3 Status Port Address 2-4 Custom Status Port Addresses 2-4 Interrupt…

Pagina 17

Introduction Hardware installation involves configuration of the Echo adapter. Note: Please refer to Chapter 3: Software Installation for installation…

Pagina 18 - WARNING

Port Addresses You configure port addresses with DIP switches 1 to 5 on SW1. Switches 3 to 5 select a set of port addresses for the ports, while you…

Pagina 19

Custom Port Addresses You can generate other port addresses by making changes to the programmable logic found on the Echo adapters. If you require…

Pagina 20

Status Port Address The Echo board provides a status port that indicates which ports, if any, are causing the interrupts. When read, the port will…

Pagina 21 - 3 4 5 7 10 11 12 15

Interrupt Selection You can configure Echo boards to use one, two or no interrupt request lines. To select the appropriate configuration, you must…

Pagina 22

Many other devices such as the keyboard and disk drives also require an IRQ. Table 3 shows some typical IRQ assignments. Table 3: Typical IRQ…

Pagina 23

Installing the Echo Adapter in your System To install your Echo adapter in your computer follow these steps: Computer components are very sensitive to…

Pagina 24

Chapter 3: Software Installation Introduction 3-1 Configuration 3-1 DOS 3.XX - 6.XX 3-2 COMSET.EXE 3-2 DFLEX.SYS 3-3 CTIMODE 3-3 Accessing Ports 3-3…

Pagina 25

Chapter 3: Software Installation 3-1 Echo User's Manual, ver. 0.00 Introduction Echo boards are standard multi-port serial adapters that utilize…

Pagina 26

DOS 3.XX - 6.XX Many DOS applications are designed to directly control the hardware of an 8250 style UART. For some applications, the DOS device…

Pagina 27

DFLEX.SYS DLEX.SYS is a device driver that allows you to set port addresses for software access of up to 32 ports . To install the device driver, add…

Pagina 28

Character Device Access Character device access provides a "high level" interface which is appropriate for simple applications and tests. Each port is…

Pagina 29

Function 0 - Initialize the port Input: ah = 0 al = baud, parity, length dx = channel ( 0 = com1, 1 = com2, ... ) Bit designations for al are: 7 data…

Pagina 30

Function 2 - Receive character Input: ah = 2 dx = port number Return: ah = port status ( timeout if bit 7 is set ) al = character received Function 3…

Mostra tutte le 79 pagine
Pagina 31 - Download Zone or the

Chapter 3: Software Installation - Linux 3-7 Echo User's Manual, ver. 0.00 Linux Linux is a leading multi-user, multi-tasking operating system for…

Pagina 32

8 Chapter 3: Software Installation - Multiuser DOS Echo User's Manual, ver. 0.00 Multiuser DOS 7 GOLD This section describes how to install an Echo…

Pagina 33

Chapter 3: Software Installation - Multiuser DOS 3-9 Echo User's Manual, ver. 0.00 7. Provide all of the Port Details after assigning the port. Set…

Pagina 34

10 Chapter 3: Software Installation - Multiuser DOS Echo User's Manual, ver. 0.00 Figure 4: Multiuser DOS: switch settings Reserved - must be OFF Base…

Pagina 35

QNX 2.XX When installing Echo boards under the QNX 2.XX operating system, it is important to note the following: Note: 1. After booting, QNX looks for…

Pagina 36

Figure 6: QNX 2.XX: switch settings Reserved - must be OFF Base address sets: Port 1 = address 280 hex Port 2 = address 288 hex Status port address…

Pagina 37

Use the stty intcp command to vector the selected interrupt to the serial handler and the stty inton command to enable that interrupt. Note: You can…

Pagina 38

QNX 4.XX controls standard serial devices in a system with its standard serial port driver Dev.ser. When installing Echo boards under the QNX 4.XX…

Pagina 39

-X Disable software flow control (default) -w Enable hardware shutdown on SIGPWR -W Disable hardware shutdown on SIGPWR (default) Many computers…

Pagina 40

Figure 8: QNX 4.XX: switch settings Reserved - must be OFF Base address sets: Port 1 = address 280 hex Port 2 = address 288 hex Status port address…

Pagina 41

The command line example shown below assumes that COM1 and COM2 are port 1 and port 2 on the Echo adapter. Example: Dev.ser 3f8,4 2f8,3 310,4 318,3…

Pagina 42

Figure 11: QNX 4.XX: IRQ settings IRQ J1 Note: All Echo odd ports are interrupting on channel A, IRQ 4 and all Echo even ports are interrupting on…

Pagina 43

QNX 6.XX For information about installing the Echo adapter for the QNX 6.XX operating system, please go to the Download Zone or the Knowledge Database…

Pagina 44

SCO Unix This section describes how to setup an Echo adapter for operation under SCO Unix. Configuration Step 1 You can setup your Echo adapter for…

Pagina 45

Technical Tip 1. You can run under DOS the DOS programs porttest.exe and portfind.exe to verify your settings and assure you have no hardware…

Pagina 46

Figure 13: SCO Unix: IRQ settings IRQ J1 Note: All ports are interrupting on channel A, IRQ 10 Step 2 You now must make an entry for the Echo adapter…

Pagina 47

Where: [COM] This parameter allows you to assign a COM to the serial adapter. There are four available COM assignments under SCO Unix.: 0 = COM1 1 =…

Pagina 48 - 8,MCRBIT3},/*AT-Echo-8*/

[Device description] A comment field used to describe the device 3. Make a copy of this entry and modify it to reflect the settings of your Echo…

Pagina 49

Step 3 You now must modify the SER file to insure the proper alignment of the minor numbers. 1. Change the directory to the /usr/lib/mkdev/perms…

Pagina 50

Step 4 You now must run mkdev serial which creates special device files to interface with the operating system’s serial driver. When running mkdev…

Pagina 51

Other Configurations It is possible to run your Echo board using I/O addresses and interrupts other than those listed above. In order to do this, it…

Pagina 52

28 Chapter 3: Software Installation - Solaris Echo User's Manual, ver. 0.00 Solaris For information about installing the Echo adapter for the Solaris…

Pagina 53 - Download

Windows 95 allows you to add up to 128 serial ports to your computer system. The Windows 95 standard serial port driver supports IRQ sharing (if the…

Pagina 54

Echo Enhanced Driver The Connect Tech enhanced serial port driver extends the functionality of the standard Windows 95 Device driver to include…

Pagina 55

Installation The following instructions outline how to install the Echo Enhanced Driver on a previously uninstalled Connect Tech Echo port. 1. If the…

Pagina 56

UART/FIFO Configuration To configure the Echo Enhanced Driver for the appropriate UART type please follow these steps: 1. From the CONTROL PANEL…

Pagina 57

Configuration The following installation assumes that your computer system comes with two standard serial ports, COM1 (at 3F8, IRQ 4); and COM2 (at…

Pagina 58

Choose an IRQ for your Echo. It is possible to have the even ports on one IRQ and the odd ports on a different IRQ, but we recommend having all ports…

Pagina 59

A window will now appear with the headings RESOURCE TYPE and SETTING. The settings shown are probably wrong. Do not worry we will change them later.…

Pagina 60

The SYSTEMS SETTINGS CHANGE window will appear. Click NO and repeat Steps 7 through 9 until you have setup all your Echo serial ports. Click YES when…

Pagina 61

Windows NT allows you to add up to 255 serial ports to your computer system. The Windows NT serial port driver supports IRQ sharing (if the hardware…

Pagina 62

Figure 16: Windows NT: switch settings When ON , p ort 1 is COM1 ( 3F8 hex ) When ON, port 2 is COM2 (2F8 hex) Reserved - must be OFF Base address…

Pagina 63

Figure 17: Windows NT: IRQ settings IRQ J1 Note All Echo ports interrupt on Channel A, IRQ 10. Technical Tip You can run under DOS the DOS programs…

Pagina 64

Click the DONE button but do not select the REBOOT option yet. 13. Repeat steps 7 through 12 for the remaining Echo serial ports, each time specifying…

Pagina 65

Method B This method is more complex than Method A and involves writing information regarding the Echo status port to the Windows NT registry. Since…

Pagina 66

19. Choose EDIT, then ADD VALUE, and enter in the following values EXACTLY as below. Value Name: InterruptStatus Data Type: REG_DWORD Value: 2C0…

Pagina 67 - COM1, COM2..., etc., for

Technical tips 1. You can test the additional serial ports with a program like Terminal or HyperTerminal. 2. A test program is available on the DFlex…

Pagina 69 - Chapter 4: Appendices

Chapter 4: Appendices Appendix A: Specifications 4-1 Operating Environment 4-1 Power Requirements 4-1 PC Bus Interface 4-1 Communications 4-1 Control…

Pagina 71 - Appendix A: Specifications

Chapter 4: Appendix A - Specifications 4-1 Echo User's Manual, ver. 0.00 Appendix A: Specifications Operating Environment Storage temperature: -60 C…

Pagina 72 - Male DB-9 Connector

Appendix B: Connectors/Pinouts Appendix B outlines the pinouts for the following: Echo cable connector pinouts Echo external connector box pinouts…

Pagina 73 - Table 6: Echo DB-78 pinouts

Table 6: Echo DB-78 pinouts Pin No. Port No. RS-232 Signal RS-485 Signal 1 5 RTS RTS A(-) 2 5 CTS RTS B(+) 3 5 Reserved CTS A(-) 4 5 Reserved CTS B(+)…

Pagina 74

Table 6(continued): Echo DB-78 pinouts Pin No. Port No. RS-232 Signal RS-485 Signal 40 1 RTS RTS A(-) 41 1 CTS RTS B(+) 42 1 Reserved CTS A(-) 43 1…

Pagina 75 - Male DB-9 connectors

Connector Box /Pinouts You may order the Echo with an external I/O Box option. The I/O Box option comes with a metal bracket that can be mounted on a…

Pagina 76

Table 7: DB-9 pinouts - Echo I/O Box Pin No. RS-232 Signal RS-485 Signal 1 DCD RxD B(+) 2 RxD TxD B(+) 3 TxD TxD A(-) 4 DTR RxD A(-) 5 SG SR 6…

Pagina 77 - Appendix C: Factory Settings

Chapter 4: Appendix C - Factory Settings 4-7 Echo User's Manual, ver. 0.00 Appendix C: Factory Settings Appendix C summarizes the factory settings for…

Pagina 78

8 Chapter 4: Appendix D: RS-422/485 Wiring Diagram Echo User's Manual, ver. 0.00 Appendix D: RS-422/485 Options RS-422/485 Cable Wiring You can wire…

Pagina 79

Chapter 4: Appendix D - RS-422/485 Options 4-9 Echo User's Manual, ver. 0.00 Figure 20 describes a 2 wire cabling scheme between a port on the Echo…